Portable calibrator calibration

A portable calibrator may work with replaceable pressure modules, probes or leads in addition to its built-in electrical functions. A field kit number will not always identify the module that supplied a recorded value.

Send an enquiry
Portable calibrator — equipment illustration
Equipment illustration
On this page

Which modules belong to the field kit?

A field kit can belong to one technician while its pressure modules move between shifts. If the calibration certificate is filed under the kit number alone, the next user cannot tell which module supplied the reference. List the modules that go with this job, the ranges you use and whether the calibrator sources or measures each quantity. Mention battery or external operation if the work instruction specifies it.

Portable calibrators used in the field

Give each detachable item an identity and state which functions must be checked together. Record the normal battery or external-power arrangement and any field configuration that changes the output. Include actual working points rather than the widest printed rating, so the agreed report follows how the kit is issued to maintenance.

Specifications and service checks

A handheld used with a battery in the field and a dock at the bench may show a discrepancy only in one configuration. Identify the module, power arrangement and leads in use when the problem appeared, particularly for low-level signals.

Range and configuration
Record the electrical input or output, sensor table and polarity. A displayed temperature can represent a simulated resistance or a thermocouple voltage.
Manufacturers and models
Fluke 725 is a portable multifunction process calibrator. Its temperature simulation, loop and voltage functions require different reference arrangements.
What we check
Compare measurement and source modes independently for the functions used. Include the reference-junction mode for thermocouple work and lead configuration for RTDs.
Reference equipment and accuracy
Use a traceable electrical calibrator, reference meter, resistance standards and appropriate temperature reference as the configuration requires.
When to repeat the check
Review calibration history against field exposure, terminal condition and module changes. Keep the due date and drift record for detachable pressure or electrical modules with the correct serial number.

Technical references Fluke 725 Multifunction Process Calibrator