Pt100 sensor calibration

A Pt100 has a nominal resistance of 100 ohms at zero degrees Celsius. Lead arrangement matters because the resistance of the connection can contribute to the reading. Identify whether the probe has two, three or four leads and include extension wiring that belongs to the assembly.

Send an enquiry
Pt100 sensor — equipment illustration
Equipment illustration
On this page

Probe wiring and the transmitter range

In a four-wire Pt100 assembly one sensor has two lead connections at each end. In a three-wire assembly the lead compensation relies on the intended wiring arrangement. Copy the wiring designation from the probe or drawing. For a sensor-only job, identify the temperatures where resistance is needed. If the transmitter reading is what goes into your process record, include its tag and range too.

Pt100 probe and readout combinations in the scope

Record the probe tag, display serial number, input channel and lead arrangement used during normal work. If the readout stores a correction for that probe, include the configuration reference. A spare probe with the same Pt100 marking should not silently replace the one named on the request.

The permanent-facility thermal entries in CC-4643 list the stated RTD or Pt100 sensor and instrument combinations over −30 to 100 °C and 100 to 250 °C. The site entry for those combinations lists 100 to 250 °C. Match the assembly and required points to the relevant entry. These entries should not be read as a blanket statement for every bare RTD, Pt1000 probe or site temperature range.

A readout shared between machines can use several RTD assemblies. Each sensor-and-channel combination requiring a result should retain its own identification. Installed components remain distinguished from removable sensors so the calibration record follows the assembly actually used for the temperature reading.

Specifications and service checks

A head marked Pt100 can have two, three or four leads. If the plant extends the cable before it reaches the input card, identify the wiring arrangement and whether the extension is part of the check. Lead resistance can otherwise be mistaken for a temperature difference.

Range and configuration
Pt100 identifies a nominal resistance of 100 Ω at 0 °C. WIKA lists different limits for wire-wound and thin-film constructions and different tolerance classes.
Manufacturers and models
WIKA documents Pt100 and Pt1000 resistance assemblies in its TR10 family. Confirm the element, tolerance class and wiring from the instrument record.
What we check
Compare the sensor with a reference thermometer and report resistance or temperature error at the required points. Include its wire configuration and any transmitter fitted in the head.
Reference equipment and accuracy
Use a calibrated platinum reference, controlled bath or block and a traceable resistance readout. A Class A or B label describes a tolerance envelope; a reference needs known uncertainty and corrections.
When to repeat the check
Track resistance at a repeatable check point. Mechanical shock, high-temperature service and a change in lead configuration are reasons to recheck sooner.

Technical references WIKA TR10 and TC10 operating instructions · BIPM guide to industrial platinum resistance thermometers · Endress+Hauser temperature measurement