On this page
Sensor history over the working interval
Include the sensor serial number, previous report, working interval and any readings you have kept at a check point. If the request involves a fixed-point or interpolation procedure, identify that requirement explicitly so the proposed result is suitable for the intended reference work.
If the probe is normally used with a particular bridge or readout, distinguish a probe calibration from a check of the full measuring pair. A correction entered into that readout may already be affecting the displayed temperature. Give the report reference for the correction and identify which value your quality record retains.
Standard platinum resistance thermometers
Say whether you require comparison points, resistance ratios or fixed-point work. These are not interchangeable requests. RTS calibrates standard platinum resistance thermometers by the specified comparison or fixed-point method; identify any SSPRT used as the reference separately from the thermometer under test.
Specifications and service checks
When a precision bridge stores several sets of interpolation coefficients, a selection from an older calibration can shift the displayed temperature even with the same probe. Match the probe serial number and coefficient issue date in the bridge configuration before comparing readings.
- Range and configuration
- Fluke’s 5681 is a 25.5 Ω quartz-sheathed SPRT with a published −200 to +670 °C range. Certificates specify the subrange over which their interpolation coefficients apply.
- Manufacturers and models
- Fluke Calibration lists the 5681 and related SPRTs with different sheaths and operating ranges.
- What we check
- A fixed-point calibration establishes the applicable interpolation data; comparison over an agreed subrange answers a narrower question. Identify which certificate the laboratory needs for its reference work.
- Reference equipment and accuracy
- Appropriate fixed-point references, a calibrated ratio bridge and standard resistor support high-accuracy work. Evaluate the whole resistance-ratio chain and the probe’s stability.
- When to repeat the check
- Maintain a history of resistance at a reproducible check point. Review drift after transport or thermal excursions before putting the probe back into reference service.
Technical references Fluke Calibration reference thermometer catalogue · BIPM guide to industrial platinum resistance thermometers

