Temperature sensor calibration

A tag that says temperature sensor can refer to a resistance element, a thermocouple, a thermistor or a device with a transmitter built in. The first step in identifying the work is to read the output type and the connection drawing.

Send an enquiry
Temperature sensor — equipment illustration
Equipment illustration
On this page

Checking the element or the input channel

For an installed probe that is hard to reach, give its insertion length and the channel that receives its signal. A comparison at a known temperature checks the sensing element. Applying an electrical input at the terminals checks the receiving channel. Tell us which check your maintenance team needs.

Unspecified temperature sensors

Give the sensor label, probe dimensions, wiring and any paired indicator. State whether you need a temperature result or an electrical output such as resistance or voltage. This information identifies the RTD, thermocouple or other sensor configuration and the reference needed for its calibration.

Specifications and service checks

A machine drawing may use one generic sensor tag for several replacement options. Copy the marking on the installed element and identify the lead arrangement. It resolves whether the input reads a resistance, a thermocouple voltage or a signal already converted in a transmitter.

Range and configuration
Start with the sensor principle. A Pt100 measures a change in resistance, a thermocouple produces a voltage, and a transmitter may convert either signal into current. The fitted assembly determines the usable span.
Manufacturers and models
WIKA’s TC10 and TR10 families illustrate thermocouple and resistance sensors respectively. The part number identifies which method applies.
What we check
Identify the sensing principle before the comparison. For a thermocouple, record its voltage or indicated temperature with a defined reference junction. A resistance sensor requires the corresponding resistance measurement instead.
Reference equipment and accuracy
Use a reference thermometer appropriate to the temperature band and a traceable millivolt or resistance readout matched to the sensor. Record the cable and junction arrangement.
When to repeat the check
High-temperature exposure and mechanical damage can change a sensor’s response. Use a check at a working temperature to review the site’s next recall.

Technical references WIKA industrial thermocouples · EURAMET thermocouple calibration guide