Time interval counter calibration

A time interval counter measures the separation between a start event and a stop event. Trigger level, edge direction and which input receives each event affect the reported interval.

Send an enquiry
Time interval counter — equipment illustration
Equipment illustration
On this page

Which event starts and stops the counter?

Give the start and stop channels, edge polarities, threshold settings and timing range. If both events travel through different cables, identify the reference connection for the result. Distinguish a single-shot interval from a value averaged over repeated events.

A rising edge on channel A and a falling edge on channel B define a different interval from two rising edges. Include the edge choices and voltage thresholds on a result used to compare the delays of two pulse paths.

Specifications and service checks

A measured delay can include propagation in two different test cables. If a fixture checks small channel-to-channel delays, identify the cables and triggering edges used at each input. A cable change can affect the interval even if the timebase is stable.

Range and configuration
For a periodic signal at 1 MHz, one period is 1 µs. Interval measurements between two channels also depend on trigger levels and path delay.
Manufacturers and models
Keysight 53230A is a universal frequency counter and timer. The selected channels, input options and timebase determine the measurement setup.
What we check
Compare frequency readings with a reference signal; for time intervals use defined edge pairs and check the channel combination used in service.
Reference equipment and accuracy
Use a calibrated two-edge time-interval source and suitable timing cables. For very short intervals, measure or account for the difference in delay between the start and stop paths.
When to repeat the check
Track the internal timebase separately from checks made while locked to an external reference.

Technical references Frequency Counters: 53230A

Enquire about Time interval counter

Time interval meter

Name the input that starts the timer, the one that stops it, and which edge triggers each. The interval from a pulse rising to its falling edge gives the pulse width. The interval between successive rising edges gives the period. Both can be recorded in milliseconds but describe different events.

Two sensors on a production line may generate pulses of opposite polarity. If the interval is measured between particular edges, list the edge selected for each sensor. Measuring to the trailing edge adds the pulse width to the intended transit time.

What we check
Compare start-to-stop intervals against independent timed pulses. Include the trigger level and edge on each input, since a slow rising edge can shift the measured interval.
Reference equipment and accuracy
Use an independent calibrated frequency reference and suitable time-interval source. Account for trigger uncertainty and channel skew at short intervals.

Shared with Time interval counter — Range and configuration · Manufacturers and models · When to repeat the check · Technical references

Enquire about Time interval meter