On this page
Matching the rule to its fitted heads
List the heads actually used, identify the rule and mark the face that locates on the workpiece. Where the protractor is used at selected settings, include those angles. If components from more than one set are mixed, record the combinations to which the results apply.
The protractor head in a combination set
For a combination-set protractor head, we compare the angular indication against an angle gauge block set or a vision measuring machine. The permanent-facility entry in CC-4643 specifies 0° to 180° at a least count of 1°. List squareness, centring or length measurements separately if you also need results for the other heads or blade.
List the protractor head and blade together, with any identifying marks that keep them paired. Give the angles used by your inspection procedure and indicate the reference face. If the head can be read in more than one orientation, show the one used on the job. Send a sketch where the required angle could be taken between different faces.
A loose clamp or replaced blade belongs in the condition note. Include any earlier result you need repeated, then identify which other heads require separate checks. The final report should let the toolroom distinguish the angular result from a separate examination of the square head or centre head.
Specifications and service checks
After the slide is moved to the far end of the rule, a small gap at the stock can alter how the head sits. If a layout line changes after repositioning, identify the location and the edge used for marking.
- Range and configuration
- The Starrett 9-12-4R includes a 12 inch rule. The RTS scope gives 0–180° for the angle portion of a combination set with 1° least count.
- Manufacturers and models
- Starrett 9-12-4R is a set with multiple heads. List only the heads that will be submitted.
- What we check
- Check the rule graduations and the working angles of the fitted heads as separate functions. Repeat after removing and reseating the head if that is routine use.
- Reference equipment and accuracy
- Use calibrated angle blocks or a vision measuring system for angles and a traceable length scale for the rule. Identify each head in the report.
- When to repeat the check
- Check for looseness and wear in the head slot between recalls. A replacement rule can alter the assembled result.
Technical references Starrett Combination set reference · CC-4643 calibration scope, page 16