+91 70565 55582[email protected]Get a quoteRequest a call
RTS Calibration
Menu

Polarimeter testing

A polarimeter measures optical rotation, while some displays convert that measurement to a product-specific scale. State whether the required result is an angle or a converted value. The wavelength, measuring tube and temperature convention are important identifiers for the check.

Send an enquiry
Polarimeter — equipment illustration
Equipment illustration
On this page

The quartz reference plate and sample tube

A quartz control plate provides an assigned rotation at stated reference conditions. Its certificate identifies the plate, wavelength and temperature. A liquid sample adds a measuring tube to the job. If your routine calls for more than one tube length, give each tube its own line so the rotation check and any check on the tube can be traced separately.

Polarimeter optical rotation conditions

A quartz reference plate and a solution-based check require their own reference conditions. Keep any calculated concentration scale distinct from the underlying optical rotation. RTS measures optical rotation using the stated reference plate or solution and records the temperature, wavelength and tube arrangement.

Specifications and service checks

A quartz control plate has an assigned rotation at stated conditions. If two instruments disagree on the same plate, record their selected wavelength, temperature and angular unit first. Values in degrees of rotation and readings on a sugar scale cannot be compared as bare numbers.

Range and configuration
Anton Paar specifies ±89.9° optical rotation on its MCP 100 and MCP 150. Specific rotation and concentration displays include additional inputs beyond the measured angle.
Manufacturers and models
Anton Paar’s MCP 100 and MCP 150 list optical and calculated reporting scales.
What we check
Compare angular indication with a certified quartz control plate appropriate to the instrument wavelength. Identify the temperature correction where one is applied.
Reference equipment and accuracy
Use a control plate with stated rotation, wavelength, reference temperature and uncertainty. Temperature measurement and optical cleanliness matter near tight tolerances.
When to repeat the check
Review after optical repair, a change of wavelength configuration or a failed control-plate check. Use repeat results to set the interval.

Technical references Anton Paar MCP polarimeter specifications

Enquire about Polarimeter