Vector signal generator calibration

A vector source creates a signal from in-phase and quadrature components. Besides carrier level and frequency, the user may rely on modulation quality or the relative behaviour of the two baseband paths.

Send an enquiry
Vector signal generator — equipment illustration
Equipment illustration
On this page

Generator bandwidth and modulation quality

Identify the active modulation format, bandwidth, level, output port and internal or external reference. Give the metric used on the bench, such as error vector magnitude where applicable. A continuous-wave level check should remain identifiable separately from a modulated-signal result.

In a two-box setup the generator creates the modulated signal and the analyzer measures it. A calibration request for the generator needs the waveform file or its defining settings and the output level. A screenshot of an error-vector measurement helps, provided the units and the analyzer settings used to obtain it are visible.

Vector signal generators

Separate carrier frequency and output amplitude from modulation-quality results. Provide the test waveform and software revision where these determine the evaluation, with confidential production content removed. RTS checks the specified carrier, amplitude and modulation functions using the recorded waveform and interface settings.

Specifications and service checks

For a modulated signal, a single average power setting does not describe the peaks or the modulation quality. Identify the waveform file, symbol rate and output connector used by the receiving test set, particularly if the issue follows an update to the waveform library.

Range and configuration
Specify carrier, power, occupied bandwidth, symbol rate and modulation format. A carrier power figure alone says little about modulation quality.
Manufacturers and models
Rohde & Schwarz SMBV100B combines an RF carrier with I/Q modulation. The available RF and modulation bandwidths depend on configuration.
What we check
Compare carrier output and frequency first, then measure modulation quality on a defined reference waveform with the applicable filtering.
Reference equipment and accuracy
Use a calibrated RF power sensor and vector signal analyser with lower residual modulation error than the required limit. Record reference clock configuration.
When to repeat the check
Repeat the waveform measurement after modulator repair or changes affecting baseband generation.

Technical references R&S®SMBV100B vector signal generator

Enquire about Vector signal generator