+91 70565 55582[email protected]Get a quoteRequest a call
RTS Calibration
Menu

Witschi tester calibration

Witschi is a maker’s name used for different watch-testing instruments. A mechanical watch timing machine can report rate, amplitude or beat error, while another instrument with the same brand can measure different watch functions.

Send an enquiry
Witschi tester — equipment illustration
Equipment illustration
On this page

Which watch-tester reading is used?

Send the exact model and identify the readout used for a service decision. For mechanical timing, include the beat rate and lift-angle setting where applicable. If a microphone or pickup is part of the test, identify whether it accompanies the display unit.

On a watch timing machine, seconds per day and milliseconds may appear on the same screen. Seconds per day describe the rate result, while milliseconds may describe beat error. A photograph of the screen with its units intact helps us quote the particular output your repair bench uses.

Witschi testers for watch measurements

Identify the exact tester and the outputs for which verification is needed. Include beat-rate and lift-angle settings where applicable, along with the microphone assembly. RTS verifies the specified watch-measurement functions using the manufacturer’s procedure, recording the reference signal, pickup and operating settings.

Specifications and service checks

Watch rate can change with movement position, while a timing machine can also report beat error and, on suitable models, amplitude. Identify the reference movement or simulator and the displayed parameter being checked. A seconds-per-day observation alone cannot establish all functions.

Range and configuration
Rate may be shown in seconds per day and beat error in milliseconds. An incorrect lift-angle setting can change the amplitude result while the rate still appears plausible.
Manufacturers and models
Witschi Watch Expert reports rate, amplitude and beat error for mechanical watch movements. Identify the lift angle and beat rate used for a measurement.
What we check
Compare the timebase and rate indication with a characterised beat signal. Amplitude and beat-error checks require a reference signal representing those properties.
Reference equipment and accuracy
Use a traceable frequency reference and suitable watch-test simulator or manufacturer verification arrangement. Define the beat pattern and pickup configuration.
When to repeat the check
Review after pickup service or a firmware change and track the response to a stable simulated movement.

Technical references Witschi Watch Expert timing instruments

Enquire about Witschi tester

Service enquiry